Skip to content
All lessons

09

How to read a peptide lab report

How to read a certificate of analysis (COA): identity, purity, amount, sterility and endotoxins.

3 min read

What you’ll learn

  • Know what the main lab tests measure.
  • Check that a certificate matches the batch you actually have.

Start with the batch number

A certificate of analysis (COA) is a lab report on a sample of a product. First check the product name, the batch or lot number, the lab that did the testing, the date and the test methods. The batch number should match your vial; a report for a different batch tells you about that batch, not yours.

Then look at what was tested. Is it the right peptide (identity)? How much is in the vial (amount)? How clean is it (purity)? Was it tested for germs (sterility) and bacterial toxins (endotoxins)? Each needs its own test, because one test can’t answer all of them.

Purity and amount aren’t the same

HPLC is the test behind most purity figures. It separates out everything in the sample, and the purity percentage shows how much of what it detected was the peptide. It doesn’t tell you how many milligrams are in the vial.

So “99% HPLC purity” and “5 mg per vial” answer different questions. The first is about how clean it is; the second is about how much there is, which needs a separate content test. A vial can be very pure and still be under-filled, so look for both numbers.

Identity and strength need their own tests

Mass spectrometry (MS) checks the weight of the molecule to confirm it’s the right peptide. It sometimes takes extra testing to tell very similar peptides apart. For example, when researchers analysed a product sold as TB-500, they found it was a short seven-amino-acid fragment of thymosin beta-4, not the full protein.

Potency is a different question again: how biologically active the product is. The right identity and high purity are good signs, but they don’t measure whether it works. Read each result as the answer to the test that produced it.

Sterility and endotoxins are separate

A sterility test checks for live bacteria and fungi. An endotoxin test checks for bits of bacteria that can still cause fever and inflammation even when the bacteria are dead. A high HPLC purity doesn’t cover either one. The report should name each test, the limit and the result.

A good COA has a batch number you can match and clearly named tests. “Not tested” is not the same as “passed”. Many people also send samples to independent labs such as Janoshik to double-check a seller’s report. The sample report below lets you practise reading one.

Check yourself

1. What does an HPLC purity percentage mainly show?
2. What links a report to your vial?
3. Why are endotoxin and sterility tests separate?

Try it yourself

Practise on a sample COA

This certificate is entirely fictional. The numbers are made up for practice, not lab results for a real peptide or batch.

Demonstration only — not a valid certificate

Certificate of Analysis

Sample: Hypothetical peptide P-Example · Report: DEMO-COA-042

Batch traceability

Check that the batch number on the report matches the one on your vial. A match is a good sign, but it only shows the lab tested a sample from that batch, not every vial in it.

Example purity chart

A made-up example of the chart behind a purity number. A tall main peak looks good, but on its own it doesn’t prove purity.

Time (example)Main peak

Compare incomplete reports

Switch between these made-up reports to see why one good result doesn’t replace the other tests.

  • Batch traceability: Not shown
  • Mass spectrometry: Reported (not checked)
  • HPLC area percentage: Reported (not checked)
  • Quantitative content: Not shown
  • Sterility / endotoxins: Not shown
  • Laboratory verification: Not shown

This report shows identity and purity, but not how much is in the vial or whether it’s sterile, and the lab hasn’t been checked.

Report authenticity exercise

A report can say anything. Practise checking it from the outside: answer each question using what you found yourself, not what the report claims.

1. Can the lab be independently contacted, using details you found yourself?
2. Has the lab authenticated this report number and date?
3. Do the sample details and chain-of-custody match what you have?
4. Can you check the test methods and the lab’s accreditation scope?
No checks recorded yet.

COA checklist

Tick each item as you check it. This helps you read a report; it doesn’t approve a product.

Reviewed 0 of 8 items.

Download the checklist

Check your understanding

Pick an answer to see if you’re right. These test how you read a report, not whether a product is safe to use.

1. A report shows 99.1% HPLC purity but no test of the amount. What does that tell you about how much peptide is in the vial?
2. The report has a lab logo and says the lab is ISO/IEC 17025 accredited. What’s the best next step?
3. The report has no sterility or endotoxin results. How should you read that?

0 of 3 correct · 0 answered.

Sources and further reading

Rewritten and sources checked 2026-10-26.